Deister proxSafe

The Deister proxSafe integrated system provides asset management system integration.

Setup

See the Data Servers page for information on configuring driver communication.

Compatibility

The Deister proxSafe integrated system is compatible with Commander 4.X.

Prerequisites

Software Minimum Version
IPFusion — Deister proxSafe 1.1
.NET Framework 4.7.2

When completing your setup, be sure to have the Deister proxSafe documentation available for reference.

Ports

These ports must be open in your network firewall for the integration to work.

Purpose Default Value Configurable
Communication Settings 8095 Yes
Dataserver 9616 Yes
Debug Tools 9617 No

Communication Configuration

In the integrated system configuration panel, you will find the Communication Settings. The below information is required.

Address The IP Address or host name of the Deister proxSafe server.
Port The Port number for the Deister proxSafe server connection.
Username The Username of the desired user to log in as on the Deister proxSafe server. This is typically a user created specifically for the Runtime connection.
Password The Password of the desired user to log in as on the Deister proxSafe server.
Database Name The name of the Database for the Deister proxSafe service.
Database Instance The Instance of the Database for the Deister proxSafe service.
Polling Interval (s) The time in seconds between requests for data.
Note: Red X indicates an invalid or out of range value given for field.

Assets

System Asset

This asset represents the connection state of the system.

View all properties

Supported States

Normal The asset is online and in its default state.
Masked The asset has been masked over its true state.
Fault An issue has been detected in a connected asset.
Acknowledged An asset alarm has been acknowledged.
No Communication Communication has been lost with the driver or asset. This status can also occur if the communication configuration for the system or asset is invalid.
Note: This status is required in all status tables.

See the Configure a Status Table page for more information on configuring status tables.

Workflow Integration

System Events

System events are events used to trigger Workflow actions at the system level. For more information about Workflows, see the Workflows section.

First Key Signed Out for User

A user has the ability to sign out multiple keys from the proxSafe system. When a user signs out the a key and it is the first or only key signed out, this event will occur.

Properties:

  • Card Number for Signed Out Key
  • Card Number for Returned Key

Last Key Returned for User

A user has the ability to sign out multiple keys from the proxSafe system. When a user returns keys that have been signed out and when the last key is returned, this event will occur.

Properties:

  • Card Number for Signed Out Key
  • Card Number for Returned Key

Troubleshooting